"Unable to open HW.SYS/VXD" or "Unable to open HW Device Driver" error when…

Knowledge Base Article # Q200266

Read Prior Article Read Next Article
Summary This an article that helps solve the Unable to Open HW error that appear when you start ATEasy and other Marvin Test Solutions software
  
Login to rate article

Overview

ATEasy and other Marvin Test Solutions software used HW device driver to access hardware. This article explain how to solve and error message "Unable to open HW.SYS/VXD" or "Unable to open HW Device Driver..." that appear when starting ATEasy or other software. This error usally occurs when HW was not installed properly with Administrator privileges. To learn more about HW, see What is HW?

Unable to Open HW Error
Figure 1: ATEasy Error


Solution

You can download and install the latest HW driver:
Download HW.exe setup

Or, you can Start the current HW driver manually using the command prompt as explained here:

1. Open the command prompt in Administrator mode: Open Windows Explorer, select the Windows, System 32 folder, Right-click cmd.exe and click on Run as Administratorr command. The Command Prompt window will open.

2. Type: cd\ and hit the Enter key.

3. Type: cd \Program Files\Marvin Test Solutions\HW, use Program Files (x86) when using a 64-bit machine. If that folder does not exist, you need to install HW from Marvin Test website HW product, downloads tab: Download HW

4. Now that we are in the file directory we can run the HWSetup.exe. Type: HWSetup install start  and hit enter. This will begin the install process. When it finishes running you should receive confirmation of completion and some notes.

5. We can also check the status of HW by typing the command: HWSetup status.

Installing HW
Figure 2: Command Prompt
Article Date 9/13/2014 , 5/2/2023
Keywords ATEasy, HW