Description
The GX3104 is a precision 3U PXI module that forces and senses both voltage and current over a range of ±20 V and up to ± 1 A ( channel 1) with channels 2- 4 capable of supplying up to 500 mA per channel. Total available output current from the module is 1A. The four channels are electrically isolated from the PXI power supply and share a common, isolated ground.
Features
The GX3104 employs 18-bit DACs for the sourcing of voltage and current. There are 7 current ranges, ranging from ±2.5 µA FS to ±1 A FS. Measurements employ a 24 bit ADC with programmable resolution from 18 to 24 bits. Each output channel includes SMU output connections, Kelvin (sense) connections, and a driven guard connection for low level current measurements.
Software
The board is supplied with the GXSMU library, a software package that includes a virtual instrument panel, and a Windows 32/64-bit DLL driver library and documentation. The virtual panel can be used to interactively program and control the instrument from a window that displays the instrument’s current settings and status. In addition, interface files are provided to support access to programming tools and languages such as
ATEasy®, LabVIEW, LabVIEW/Real-Time, C/C++, Microsoft Visual Basic®, Delphi, and Pascal. An On-Line help file and PDF User's Guide provides documentation that includes instructions for installing, using and programming the board.
A separate software package - GtLinux - provides support for Linux 32/64 operating systems.
Applications
- Semiconductor component test and characterization
- ATE systems
- Board and system level test
GX3104 Specifications
Hardware |
---|
I/O Connections per Channel | SMU input / output (2) Guard Kelvin (2) |
Format | PXI, 3U single slot, hybrid slot compatible |
Source and Measure Specifications |
---|
Voltage Source | Range: ±20 V FS Accuracy: 0.05% of programmed value + 2mV |
Voltage Source Resolution | 18 bits |
Output Voltage Ripple and Noise | < 20 mV p-p, 20 MHz BW, full load |
Current Source Resolution | 18 bits |
Current Source Ranges | ±25 uA to ±250 mA, in decade ranges Accuracy: ±0.05% of programmed value + 0.05% of FS range ±2.5 uA range Accuracy: ±0.05% of programmed value + 0.4% of FS range ±1 A range* Accuracy: ±0.5% of programmed value + 0.5% of FS range *Notes: -Only Channel 1 supports the 1A capability- -Channels 2-4 support up to 500 mA FS- -Maximum output current from the module cannot exceed 1A- |
Isolation Voltage | ±60 VDC relative to PXI ground |
Maximum Voltage Between the LO Terminal and PXI Ground | ±60V |
Absolute Maximum Voltage within a Channel | ±25 Volts |
Source Noise | 20 uV RMS (0.1 Hz to 10 Hz) 25 mV RMS (20 Hz to 20 MHz) |
Settling Time | 10% of current range: 10 us typical, 20 us max. 90% of current range: 100 us typical, 300 us max. |
Transient Response | Settles to ±20 mV of programmed value after 80% load change, 100 us typical, 3 ms max. |
Voltage Measurement | Range: ±20 V Accuracy: 0.05% of measured value + 2mV at 60 reading per sec. |
Current Measurement | ±25 uA to ±250 mA, in decades Accuracy: ±0.05% of measured value + 0.05% of FS range ±2.5 uA range Accuracy: ±0.05% of measured value + 0.4% of FS range ±1 A range* Accuracy: ±0.5% of measured value + 0.5% of FS range *Only Channel 1 can measure ±1 A FS *Channels 2 -4 can measure ±500 mA FS Note: all specified current measurements accuracies are done at 60 reading per sec. |
Measurement Resolution | Programmable, 18 to 24 bits |
Measurement Conversion Rate | 82 us to 2868 us, based on measurement resolution |
Environmental and Physical Specifications |
---|
Temperature Range | Operating: 0 to +40 °C Storage: -20°C to +70 °C |
Power | +12 V, 2.95 A; +5 V, 0.75 A; +3.3 V, 1.2 A Note: For high power applications, a high power chassis with 45 watts of power / cooling per slot is required |
I/O Connector | DB 25 female |
Note: Specifications are subject to change without notice.
Knowledge Base Articles pertaining to GX3104
Enhancements to ATEasy and its software drivers include support for scalable test program development, test execution time optimization, and parallel test support with existing ATEasy test code.
Read more...
Downloads for GX3104
Datasheet
GX3104DS.pdf
Mar 25, 2024
version: H
836.62 KB
Setup/Package
GxSmu.exe
Aug 7, 2024
version: 2.0.4.0
25.22 MB
Most recent Setup/Package
This Setup / Package file contains all necessary files (including user's guide, help, etc).
Expand
to view And download individual files included in the setup.
Setup/Package
GxSmuReadMe.txt
Aug 7, 2024
version: 2.0.4.0
14.57 KB
Most recent Setup/Package
Manual
GxSmuUG.pdf
Dec 26, 2023
version: 2.0.4.0
1.78 MB
On-Line Help
GxSmu.chm
Dec 26, 2023
version: 2.0.4.0
1.60 MB
Other
GX3104_Vol.pdf
Feb 11, 2019
50.58 KB
Download our PXI Catalog
Products similar to GX3104
- GX1838 Series - Precision Multi-Channel DC Source PXI Card
- GX2065 - 6.5 Digit DMM / Digitizer PXI Card
- GX3116e - 16 Channel Device Power Supply (DPS)
- GX7400A - 6U Power Supply Mainframe. Accepts Two Programmable Power Modules
Order GX3104 and Related Products
To order call
1-888-837-8297
or order on-line via the form below. Prices are specified for
USA
destination orders. Prices are noted in USD.
Import duties, taxes, and charges are not included in the item price.