Description
The GX2065 offers a unique combination of features, resolution, accuracy and speed in a compact, single slot 3U PXI format. Featuring 6-½ digit resolution, 0.005% basic DCV reading accuracy and up to 3,500 reading per second (rps) assures you of measurements that are accurate, fast and repeatable. All measurement functions including digitizing functions are isolated from the PXI bus - providing the ability to make true differential, floating measurements. An on-board controller performs all necessary DMM and digitizer calculations, minimizing PXI control bus overhead.
Features
The GX2065 is designed as a universal, multifunction DMM and provides all of the features associated with standard bench top DMMs including V
DC, V
AC, 2 and 4 - wire resistance measurements, and current measurements. Additionally, the GX2065 features a 3 MHz, 16 bit, isolated input digitizer which allows users to acquire and analyze waveforms. Built in analysis and waveform functions include RMS, average, peak to peak, and peak to average measurements. Up to 8192 samples can be stored in the digitizer’s memory. Frequency and period measurements to 500 kHz are also supported. An external TTL trigger via the PXI bus or front panel is available for triggering DMM measurements.
Software
The GX2065 is supplied with the GXDMM software package which includes a virtual instrument panel, a Windows 32/64-bit DLL driver libraries and documentation. The virtual panel can be used to interactively program and control the instrument from a window that displays the instrument’s current settings and status. In addition, interface files are provided to support access to programming tools and languages such as ATEasy, LabView, LabView/Real-Time, C/C++, Microsoft Visual Basic®, Delphi, and Pascal. An On-Line help file and PDF User's Guide provides documentation that includes instructions for installing, using and programming the board. Signametrics SMX2040 & SMX2060 and IV-C compatible drivers are also supplied, allowing customers to easily interchange other vendors DMMs (for example SMX2040 from Signametrics or PXI-4070 or PXI-4072 from NI) with the GX2065 without changing the application code.
A separate software package - GtLinux - provides support for Linux 32/64 operating systems.
Applications
- Automated production testing
- Laboratory automation
- Portable/field test
- Semiconductor and component test
GX2065 Specifications
General Specifications |
---|
Inputs | Hi, Lo, Hi Sense, Lo Sense; floating and isolated from ground External trigger |
Input Connectors | (4) Banana, 6-pin DIN |
Format | PXI, 3U single slot, hybrid slot compatible |
DMM and Digitizer Measurement System Features |
---|
Resolution | 22 bits (DMM), 16 bits (digitizer / DAQ) |
DMM Sampling Rate (VDC, IDC & R Measurements) | Selectable PLC rate, 0.002 to 10; PLC can be set to 50 or 60 Hz |
DMM Reading Rate (VDC, IDC & 2WR (< 10 M ohm)) | 5 readings/sec @ 6.5 digits, 60 Hz, (10 PLC), Auto Zero Off 50 readings/sec @ 6.5 digits, 60 Hz, (1 PLC), Auto Zero Off 500 readings/sec @ 5.5 digits, 60 Hz, (0.1 PLC), Auto Zero Off, 1K samples into buffer 2500 readings/sec @ 4.5 digits, 60 Hz, (0.01 PLC), Auto Zero Off, 1K samples into buffer 3500 readings/sec @ 3.5 digits, 60 Hz, (0.002 PLC), Auto Zero Off, 1K samples into buffer |
Digitizer (DAQ) Clock Rate | Programmable to 3 MHz Range: (3 MS/s) / N, N=1 to 216 Accuracy: 100 ppm |
DAQ Measurement Functions | AC / DC voltage and current measurements |
Digitizer Memory | 8192 samples |
DMM Memory | 1 K samples |
DMM Measurement Characteristics |
---|
Input Range | 100 nV to 300 V |
VAC Input Range | 3 µV to 425 V (peak), 300 VRMS 10 Hz to 300 kHz, AC or DC coupled |
Crest Factor (VAC) | No limitation as long as maximum input signal is below the peak range value. |
VDC / VAC Input Impedance | > 10 GΩ (0.1, 1, and 10 VDC ranges) 400 pF shunt capacitance 10 MΩ for other AC / DC ranges, 400 pF shunt capacitance |
Maximum Input (Volt - Hertz) | 8 x 10e7 V x Hz Common Mode Input 8 x 10e7 V x Hz (across Hi or Lo input relative to earth ground) |
Input Isolation | CATII 300 V |
Input Overvoltage Protection | 250 V for current input, 300 V CATII for all other inputs |
Noise Rejection | VDC: 90 dB, NMRR; 140 dB CMRR 15 readings/s, 1 PLC, 6.5 digit, 10 V range VAC: 70dB, CMRR |
IDC Input Range | 10 nA to 2 A |
IAC Input Range | 3 µA to 2 A peak, AC coupled 10 Hz to 5 kHz |
Crest Factor (AC Current) | No limitation as long as maximum input signal is below the peak range value |
AC / DC Input Current Protection | 2 A, 250 V, fast blow, sand filled, 1.5 kA breaking |
Resistance Range | 100Ω to 100 MΩ |
Resistance Measurement Configuration | Selectable, 2-wire or 4-wire |
Burden Voltage | 20 mA range, < 0.2 V 100 mA range, < 0.1 V 1 A range, < 0.5 V 2 A range, < 1.0 V |
Internal Temperature Measurement Accuracy | ± 2°C |
Time Base Accuracy | 100 ppm |
Triggering |
---|
Trigger Source | Function: Start measurement Source: PXIbus, software, continuous, external input (DIN connector), timer |
Trigger Output Modes | Functions: Start of measurement, end of measurement Trigger can be routed to the PXIbus or the DIN connector |
Trigger Input Voltage Range | 3.3 V CMOS, 5 V Tolerant |
Minimum Trigger Input Pulse Width | 50 ns for PXI bus, 250 µs for external DIN input |
Trigger Input Impedance | 4.75 kΩ |
Trigger Input Edge | Selectable, positive or negative |
AC Measurement Performance |
---|
Reading Rate | Signal Bandwidth |
1 S/s | 4 Hz to 4 kHz |
5 S/s | 20 Hz to 20 kHz (default) |
375 S/s | 300 Hz to 300 kHz |
DC Voltage Measurement |
---|
Range | Resolution | Accuracy 24 Hours 23°C ±5° (% of Reading)+ (% of FS) | Accuracy 90 Days 23°C ±5° (% of Reading)+ (% of FS) | Accuracy 1 Year 23°C ±5° (% of Reading)+ (% of FS) |
100 mV | 100nV | 0.0030 + 0.0040 | 0.0040 + 0.0045 | 0.0045 + 0.0045 |
1 V | 1 µV | 0.0030 + 0.0007 | 0.0040 + 0.0008 | 0.0045 + 0.0008 |
10 V | 10 µV | 0.0010 + 0.0004 | 0.0025 + 0.0005 | 0.0030 + 0.0005 |
100 V | 100 µV | 0.0030 + 0.0006 | 0.0050 + 0.0009 | 0.0060 + 0.0009 |
300 V | 1 mV | 0.0030 + 0.0020 | 0.0045 + 0.0030 | 0.0060 + 0.0030 |
DC Voltage Measurement, DAQ Mode |
---|
Range | Resolution | Accuracy 24 Hours 23°C ±5° (% of Reading)+ (% of FS) | Accuracy 90 Days 23°C ±5° (% of Reading)+ (% of FS) | Accuracy 1 Year 23°C ±5° (% of Reading)+ (% of FS) |
100 mV | 4µV | 0.06 + 0.06 | 0.06 + 0.06 | 0.06 + 0.06 |
1 V | 40 µV | 0.06+ 0.03 | 0.06+ 0.03 | 0.06+ 0.03 |
10 V | 400 µV | 0.06+ 0.03 | 0.06+ 0.03 | 0.06+ 0.03 |
100 V | 4 mV | 0.06+ 0.03 | 0.06+ 0.03 | 0.06+ 0.03 |
300 V | 40 mV | 0.06 + 0.10 | 0.06 + 0.10 | 0.06 + 0.10 |
DC Current Measurement |
---|
Range | Resolution | Accuracy 24 Hours 23°C ±5° (% of Reading)+ (% of FS) | Accuracy 90 Days 23°C ±5° (% of Reading)+ (% of FS) | Accuracy 1 Year 23°C ±5° (% of Reading)+ (% of FS) |
20 mA | 10nA | 0.0060 + 0.0030 | 0.030 + 0.0080 | 0.0500 + 0.0080 |
100 mA | 100 nA | 0.0100 + 0.0300 | 0.0300 + 0.080 | 0.0500 + 0.080 |
1 A | 1 µA | 0.0200 + 0.0030 | 0.0500 + 0.0080 | 0.0800 + 0.0080 |
2 A | 10 µA | 0.1000 + 0.0035 | 0.1200 + 0.0060 | 0.1200 + 0.0060 |
DC Current Measurement, DAQ Mode |
---|
Range | Resolution | Accuracy 24 Hours 23°C ±5° (% of Reading)+ (% of FS) | Accuracy 90 Days 23°C ±5° (% of Reading)+ (% of FS) | Accuracy 1 Year 23°C ±5° (% of Reading)+ (% of FS) |
20 mA | 4µA | 0.03 + 1.0 | 0.03 + 1.0 | 0.03 + 1.0 |
100 mA | 40 µA | 0.01 + 1.0 | 0.01 + 1.0 | 0.01 + 1.0 |
1 A | 40 µA | 0.04 + 0.15 | 0.04 + 0.15 | 0.04 + 0.15 |
2 A | 80 µA | 0.04 + 0.15 | 0.04 + 0.15 | 0.04 + 0.15 |
Notes:
DC measurements @ 10 PLC or 1 PLC with digital filtering
Accuracy of measurement is % of reading + % of Range
AC Volts (RMS), AC Coupled, DAQ Mode |
---|
Range (RMS) | Range (Vpk) | Resolution | Frequency and Accuracy [23°C ±5° (% of Reading) + (% of FS)] |
50 mV | 100 mV | 2 µV | Frequency | Accuracy 24 Hours | Accuracy 90 Days | Accuracy 1 Year |
3 Hz - 10Hz | 0.5 + 0.28 | 0.5 + 0.28 | 0.5 + 0.28 |
>10 Hz - 20 KHz | 0.2 + 0.28 | 0.2 + 0.28 | 0.2 + 0.28 |
>20 KHz - 50 KHz | 0.26 + 0.3 | 0.26 + 0.3 | 0.26 + 0.3 |
>50 KHz - 100 KHz | 0.75 + 0.33 | 0.75 + 0.33 | 0.75 + 0.33 |
>100 KHz - 300 KHz | 4.15 + 0.75 | 4.15 + 0.75 | 4.15 + 0.75 |
0.5 V 5 V 50 V 300 V |
1 V 10 V 100 V 450 V |
20 uV 200 uV 2 mV 30 mV | 3 Hz - 10Hz | 0.35 + 0.03 | 0.35 + 0.03 | 0.35 + 0.03 |
>10 Hz - 20 KHz | 0.05 + 0.03 | 0.05 + 0.03 | 0.06 + 0.03 |
>20 KHz - 50 KHz | 0.11 + 0.05 | 0.11 + 0.05 | 0.12 + 0.05 |
>50 KHz - 100 KHz | 0.60 + 0.08 | 0.60 + 0.08 | 0.60 + 0.08 |
>100 KHz - 300 KHz | 4.0 + 0.5 | 4.0 + 0.5 | 4.0 + 0.5 |
AC Current (RMS), AC Coupled, DAQ Mode |
---|
Range (RMS) | Resolution | Frequency and Accuracy [23°C ±5° (% of Reading) + (% of FS)] |
0.5 A | 40 µA | Frequency | Accuracy 24 Hours | Accuracy 90 Days | Accuracy 1 Year |
3 Hz - 10 Hz | 0.30 + 0.04 | 0.30 + 0.04 | 0.30 + 0.04 |
>10 Hz - 3 KHz | 0.10 + 0.04 | 0.10 + 0.04 | 0.10 + 0.04 |
>3 KHz - 5 KHz | 0.14 + 0.04 | 0.14 + 0.04 | 0.14 + 0.04 |
1.0 A | 80 µA | 3 Hz - 10 Hz | 0.35 + 0.09 | 0.35 + 0.09 | 0.35 + 0.09 |
>10 Hz - 3 KHz | 0.15 + 0.09 | 0.15 + 0.09 | 0.15 + 0.09 |
>3 KHz - 5 KHz | 0.18 + 0.09 | 0.18 + 0.09 | 0.18 + 0.09 |
Resistance |
---|
Range (ohms) | Open Circuit Voltage & Test Current | Resolution | Accuracy 24 Hours 23°C ±5° (% of Reading)+ (% of FS) | Accuracy 90 Days 23°C ±5° (% of Reading)+ (% of FS)
| Accuracy 1 Year 23°C ±5° (% of Reading)+ (% of FS)
|
100 | 6.9 V, 1 mA | 100嵽 | 0.0020 + 0.0060 | 0.0080 + 0.0060 | 0.0100 + 0.0060 |
1000 | 6.9 V, 1 mA | 1 mΩ | 0.0025 + 0.0006 | 0.0085 + 0.0020 | 0.0105 + 0.0006 |
10 K | 6.9 V, 100 µA | 10 mΩ | 0.0020 + 0.0006 | 0.0080 + 0.0020 | 0.0100 + 0.0006 |
100 K | 12.8 V, 10 µA | 100 mΩ | 0.0030 + 0.0006 | 0.0090 + 0.0010 | 0.0110 + 0.0010 |
1 M | 12.8 V, 1 µA | 1 Ω | 0.0020 + 0.0006 | 0.0020 + 0.0010 | 0.0100 + 0.0010 |
10 M | 7 V, 0.7 µA // 10 M Ω | 10 Ω | 0.0150 + 0.0006 | 0.0200 + 0.0010 | 0.0400 + 0.0010 |
100 M | 7 V, 0.7 µA // 10 MΩ | 100 Ω | 0.0800 + 0.0030 | 0.2000 + 0.0030 | 0.2000 + 0.0030 |
DC Voltage Measurement, DAQ Mode |
---|
Range | Resolution | Accuracy 24 Hours 23°C ±5° (% of Reading)+ (% of FS) | Accuracy 90 Days 23°C ±5° (% of Reading)+ (% of FS)
| Accuracy 1 Year 23°C ±5° (% of Reading)+ (% of FS)
|
100 mV | 4µV | 0.06 + 0.06 | 0.06 + 0.06 | 0.06 + 0.06 |
1 V | 40 µV | 0.06 + 0.03 | 0.06 + 0.03 | 0.06 + 0.03 |
10 V | 400 µV | 0.06 + 0.03 | 0.06 + 0.03 | 0.06 + 0.03 |
100 V | 4 mV | 0.06 + 0.03 | 0.06 + 0.03 | 0.06 + 0.03 |
300 V | 40 mV | 0.06 + 0.10 | 0.06 + 0.10 | 0.06 + 0.10 |
Diode Measurement |
---|
Test Current | Voltage Range | Current Source Accuracy | Accuracy (Nominal) 24 Hours 23°C ±5° (% of Reading)+ (% of FS) | Accuracy (Nominal) 90 Days 23°C ±5° (% of Reading)+ (% of FS) | Accuracy (Nominal) 1 Year 23°C ±5° (% of Reading)+ (% of FS) |
10 uA | 0 - 12 V | 5% | 0.001 + 0.004 | 0.0025 + 0.005 | 0.003 + 0.005 |
100 uA | 0 - 6.5 V | 5% | 0.001 + 0.004 | 0.0025 + 0.005 | 0.003 + 0.005 |
1 mA | 0 - 6.5 V | 5% | 0.001 + 0.004 | 0.0025 + 0.005 | 0.003 + 0.005 |
Frequency Measurement |
---|
Frequency Range | 1 Hz to 500 KHz |
Input Voltage* | 20 mV to 300 V |
Resolution (offset ppm) | 0.33 (1 second gate time) 3.33 (100 mSec gate time) 33.3 (10 mSec gate time) |
Accuracy | 100 ppm of reading + offset ppm |
* Input amplitude must be at least 20% of FS and input amplitude must not exceed specified volt - hertz product.
Environmental and Physical Specifications |
---|
Safety | Complies with IEC 61010-1, CAT II 300 V, pollution degree 2 |
EMC | Complies with EN61326-1 |
Calibration | Calibration is performed at the factory using NIST traceable instrumentation. All calibration constants are stored on-board in non-volatile EEROM. Calibration can be performed by any calibration laboratory with the appropriate equipment. Calibration Interval: 1 year |
Operating Temperature Range | GX2065: 0°C to +50°C GX2065-M: 0°C to +62°C; contact factory for extended temperature range specifications |
Storage Temperature Range | GX2065: -20 °C to +85°C GX2065-M: -51 °C to +85 °C |
Relative Humidity | Operating: 80% at 40 °C Storage: 95% at 40 °C |
Power (max) | +5 VDC, 2.3 A +3.3 VDC, 255 mA +12 VDC, 16 mA -12 VDC, 25 mA |
Connectors | (4) Banana jacks: Hi: Voltage, 2 W Ω Lo: Voltage, Current, 2 W Ω Sense Hi: Current, 4 W Ω Sense Lo: 4 W Ω 6-pin DIN: Trigger in, Trigger out, Trigger Gnd |
Note: Specifications are subject to change without notice.
Knowledge Base Articles pertaining to GX2065
This article demonstrates how to access Marvin Test Solutions' unmanaged DLL from PowerShell with example using the GxDmm software package to control and interface with Gx2065.
Read more...
Procedure to create a support incident using MTS’s M@GIC online support for the purposes of requesting calibration on your MTS instruments or to request an RMA.
Read more...
Q200255
May 24, 2019
White Paper
The PATS (Portable Automated Test Set)-70 is a flightline test set that is based on the MTS-207 for supporting and maintaining a variety of A-10/C systems.
Read more...
Q200236
Dec 12, 2012
White Paper
This paper discusses the requirements and techniques used to develop a PXI-based, high performance DMM. A review of the required performance parameters is presented along with an analysis of the alternative design methods employed in order to achieve the necessary performance capabilities without compromising the overall capabilities of the hardware.
Read more...
How to use the Data Acquisition Functionality of the GX2065 DMM
Read more...
Downloads for GX2065
Datasheet
GX2065DS.pdf
Mar 25, 2024
version: F
260.53 KB
Setup/Package
GxDmm.exe
Dec 12, 2022
version: 2.4.2.0
27.49 MB
Most recent Setup/Package
This Setup / Package file contains all necessary files (including user's guide, help, etc).
Expand
to view And download individual files included in the setup.
Setup/Package
GxDmmReadMe.txt
Dec 12, 2022
version: 2.4.2.0
17.28 KB
Most recent Setup/Package
Manual
GX2065UG.pdf
Dec 20, 2022
version: 2.4.2.1
1.63 MB
On-Line Help
GxDmm.chm
Dec 20, 2022
version: 2.4.2.1
865.47 KB
Other
GX2065_Vol.pdf
Apr 10, 2017
365.56 KB
Download our PXI Catalog
Products similar to GX2065
Order GX2065 and Related Products
To order call
1-888-837-8297
or order on-line via the form below. Prices are specified for
USA
destination orders. Prices are noted in USD.
Import duties, taxes, and charges are not included in the item price.